Steam-powered Stardrier |

Technical features - working width 1800-2200 mm by 3200-4200 mm cell length
|
Steam pressure
|
max 2 bar
|
|
Temperature of tunnel
|
max 120°C
|
|
Extruder airflow
|
3000 m3/h
|
|
Extruder motor power (for tunnel)
|
0,55 Kw
|
|
Steam inlet (coil)
|
DN32/PN16
|
|
Condensation outlet (coil)
|
1/2"gas
|
|
Thermal potential
|
82800 kcal/h
|
|
Airflow
|
15000 m3/h
|
|
Two-speed fan power
|
4,3/1,4 Kw - 50/60 Hz
|
|
Conveyor speed
|
5/20 m/min
|
Technical features - working width 2600-3000-3400 mm by 3200-4200 mm cell length
|
Steam pressure
|
max 2 bar
|
|
Temperature of tunnel
|
max 120°C
|
|
Extruder airflow
|
3000 m3/h
|
|
Extruder motor power (for tunnel)
|
0,55 Kw
|
|
Steam inlet (coil)
|
DN32/PN16
|
|
Condensation outlet (coil)
|
1/2"gas
|
|
Thermal potential
|
123000 kcal/h
|
|
Airflow
|
15000 m3/h
|
|
Two-speed fan power
|
4,3/1,4 Kw - 50/60 Hz
|
|
Conveyor speed
|
5/20 m/min
|
Technical features - working width 3800 mm by 3200-4200 mm cell length
|
Steam pressure
|
max 2 bar
|
|
Temperature of tunnel
|
max 120°C
|
|
Extruder airflow
|
3000 m3/h
|
|
Extruder motor power (for tunnel)
|
0,55 Kw
|
|
Steam inlet (coil)
|
DN32/PN16
|
|
Condensation outlet (coil)
|
1/2"gas
|
|
Thermal potential
|
162000 kcal/h
|
|
Airflow
|
18000 m3/h
|
|
Two-speed fan power |
6/2 Kw - 50/60 Hz
|
|
Conveyor speed
|
5/20 m/min
|
Dimensional features
|
Working width
|
A
|
|
1800
|
2290
|
|
2200
|
2690
|
|
2600
|
3090
|
|
3000
|
3490
|
|
3400
|
3890
|
|
3800
|
4290
|
|
|
|
L = cell length
|
|
3200
|
|
4200
|
|
|
Type of conveyor
|
|
Wire conveyor belt
|
|
Mesh conveyor belt
|
|
|

|
|